What Is a Gloss Meter?
Applications Across Industry
Relevant Standards for Gloss Meters
What Units Is Gloss Measured In?
Available Models Compared
Measurement Field and Aperture Selection
Which Measurement Angle Is Right: 20°, 60°, or 85°?
The Price of a Gloss Meter — Purchase Price Isn’t Everything
Calibration Standards and Measurement Consistency
Calibration Correction: Flexibility for Production Environments
Frequently Asked Questions (FAQ)
- What Is a Gloss Meter?
- Applications Across Industry
- Relevant Standards for Gloss Meters
- What Units Is Gloss Measured In?
- Available Models Compared
- Measurement Field and Aperture Selection
- Which Measurement Angle Is Right: 20°, 60°, or 85°?
- The Price of a Gloss Meter — Purchase Price Isn’t Everything
- Calibration Standards and Measurement Consistency
- Calibration Correction: Flexibility for Production Environments
- Frequently Asked Questions (FAQ)
What Is a Gloss Meter?
A gloss meter — also called a glossmeter or reflectometer — is an optical precision instrument used to quantitatively determine the reflectance of a surface. The device illuminates the surface at a defined angle and measures the intensity of the reflected light.
Unlike purely visual assessment, a gloss meter delivers repeatable, standards-compliant readings — essential anywhere uniform surface quality needs to be verified: in the paint industry, automotive production, plastics processing, printing, or furniture manufacturing.
Applications Across Industry
Gloss meters are used across a wide range of industries:
● Paint and coatings: monitoring gloss level and surface finish
● Automotive: quality assurance of body paint and interior trim
● Plastics processing: testing injection-molded and extruded parts
● Printing: measuring glossy coatings, films, and print substrates
● Furniture and wood: checking surface finishes
● Pharmaceuticals: testing tablet surfaces and packaging
Relevant Standards for Gloss Meters
3Color® gloss meters were developed based on internationally recognized standards. Before choosing a device, users should become familiar with the specific requirements of their industry and product.
The following standards govern gloss measurement:
● ASTM D523 — Standard Test Method for Specular Gloss
● ASTM D2457 — gloss measurement on plastic films and solid materials
● DIN 67530 — reflectometers as a tool for gloss measurement
● ISO 2813 — paints and varnishes: measurement angles 20°, 60°, 85°
● ISO 7668 — anodized aluminum
● JIS Z8741 — Japanese standard for gloss measurement
● BS 3900 / BS 6161 — British standards for coatings
What Units Is Gloss Measured In?
Two units are commonly used to express gloss readings in practice:
Percent (%)
The percentage of light reflected from a surface. This figure is mainly suited to simple, comparative statements.
Gloss Units (GU)
In industrial settings, GU (Gloss Units) is the standard unit of measurement. The scale is referenced to polished black glass: 100 GU corresponds to the reflectance of polished black glass, and 0.00 GU to theoretical total absorption with no reflectance at all. All 3Color® devices output readings in GU by default.

Photo 1: Micro-aperture of the GM30s gloss meter

Fig. 2: Measurement field of the GM38 multi-angle gloss meter
Available Models Compared
3Color® offers three gloss meters covering different needs in terms of angle range and measurement field:
3Color® GM30 — Single-Angle Gloss Meter
The entry-level GM30 measures gloss at a fixed 60° angle. It’s suited to applications where the gloss range is known and falls in the mid-range (10–70 GU). Compact, rugged, and simple to operate.
3Color® GM38 — Multi-Angle Gloss Meter
The GM38 is the reference device for demanding measurement tasks. It operates at three measurement angles (20°, 60°, 85°), covering the full gloss range — from high-gloss metal surfaces to matte plastics. Ideal when the gloss characteristics of the material being tested are unknown or variable.
3Color® GM30s — Single-Angle Gloss Meter with Micro-Aperture
The GM30s is built on GM30 technology but fitted with a micro-aperture (measurement field: 2 mm × 3 mm). It was developed specifically for small parts, tight geometries, and curved surfaces, where conventional devices run into limits due to their aperture size.
Measurement Field and Aperture Selection
The measurement field — the area the device uses for its reading — is an often-underestimated specification. Two factors are critical here:
● The material being tested must be large enough to fully cover the device’s minimum measurement field. If the sample is too small, the readings can’t be evaluated.
● For curved or textured surfaces, a smaller aperture is recommended to minimize the influence of surface geometry on the measurement result.
The GM30s, with its micro-aperture (2 mm × 3 mm), offers a clear advantage here over the standard models, whose apertures are designed for large, flat samples.
Which Measurement Angle Is Right: 20°, 60°, or 85°?
Choosing the right measurement angle is one of the most important parameters in gloss measurement. As a general rule, any gloss meter can measure at any angle — but the standard recommendations refer to which angle range offers the highest resolution and accuracy.
Recommended procedure with a multi-angle device (e.g., the GM38):
● Step 1: Measure at 60° first.
● Step 2: If the value falls between 10 and 70 GU, 60° is the optimal angle.
● Step 3: If the value is above 70 GU, switch to 20° (high gloss).
● Step 4: If the value is below 10 GU, switch to 85° (matte/deep-matte range).
Single-angle gloss meters like the GM30 can, in principle, also measure in the high- or low-gloss range — but measurement resolution there is lower. Anyone working regularly with surfaces of varying gloss levels should consider a multi-angle device.
The Price of a Gloss Meter — Purchase Price Isn’t Everything
The purchase price of a gloss meter varies by model, number of angles, and manufacturer. But comparisons shouldn’t stop at the list price. The following factors affect total cost of ownership:
● Calibration costs: how often does the device need to be calibrated, and what does that cost?
● Calibration standard: is a certified reference standard included? Does it come with an ISO 17025 calibration certificate?
● Service and support: does the manufacturer offer on-site service, repairs, and loaner devices?
● Software integration: can the device be integrated into existing quality management systems?
3Color® provides certified calibration standards with ISO 17025 certification for all its gloss meters, along with comprehensive after-sales support.
Calibration Standards and Measurement Consistency
A frequently underestimated issue in practical use is the consistency of gloss readings between different devices or labs. It’s not uncommon for the same calibration standard to be measured with a deviation of more than 5 GU across two accredited labs.
The cause lies in the absence of a globally valid primary standard for gloss. Every manufacturer defines its reference based on polished black glass — but with slightly different specifications. This creates systematic measurement differences that can occur even with correctly calibrated devices.
Recommendation: if consistent readings are required across a company or supply chain, all devices should come from the same manufacturer and ideally be referenced to the same calibration standard.
Calibration Correction: Flexibility for Production Environments
Since 2024, all 3Color® gloss meters have included a function for manually correcting the calibration value. The user can define the reference value of the calibration plate themselves — a feature that provides significant flexibility in practice.
A typical use case: a company supplies two customers, each using different gloss meters from different manufacturers. The readings from the two devices don’t match. With calibration correction, a separate measurement profile can be stored for each customer — without any debate over which reading is “correct.”
This feature has been rated by users as particularly practical, and is still relatively rare on devices in this price class.
Frequently Asked Questions (FAQ)
What’s the difference between a single-angle and a multi-angle gloss meter? A single-angle gloss meter (e.g., the GM30) measures at one fixed angle — typically 60°. A multi-angle device (e.g., the GM38) can measure at 20°, 60°, and 85°, covering the full gloss range in line with the standards. A multi-angle device is recommended for unknown or varying materials.
How often does a gloss meter need to be calibrated? Calibration should be performed before every measurement session. A regular check of the calibration standard by an accredited lab (ISO 17025) is recommended annually.
Why do readings differ between two gloss meters? Different manufacturers define their reference slightly differently. On top of that, there are device-specific linearity deviations in certain measurement ranges. 3Color® has addressed this issue with its calibration-correction feature since 2024.
Which 3Color® model is suited to small parts? The GM30s, with its micro-aperture (2 mm × 3 mm), was developed specifically for small and curved surfaces. It’s the first choice when the measurement field of the standard devices is too large.
Are 3Color® gloss meters standards-compliant? Yes. All 3Color® devices were developed based on the relevant international standards, including ISO 2813, ASTM D523, DIN 67530, and others.
Discover Our Products