How Does a Colorimeter Work?
How Does a Spectrophotometer Work?
The Spectrocolorimeter: The In-Between Solution
Direct Comparison: Technical Parameters Side by Side
Making the Decision: Asking the Right Questions
Frequently Asked Questions
Summary
- How Does a Colorimeter Work?
- How Does a Spectrophotometer Work?
- The Spectrocolorimeter: The In-Between Solution
- Direct Comparison: Technical Parameters Side by Side
- Making the Decision: Asking the Right Questions
- Frequently Asked Questions
- Summary
It’s the most common question before buying a color measurement device: colorimeter or spectrophotometer? The two terms are often used as synonyms — but they refer to devices with fundamentally different measurement principles, different levels of precision, and different fields of application.
Getting the answer right before purchase can make the difference between a device that meets quality-control requirements for years, and one that causes repeatability or supplier-compatibility problems right from the start.
How Does a Colorimeter Work?
The colorimeter is the oldest color-measurement device. Its operating principle is modeled directly on the physiology of the human eye: the light reflected by the sample is split by three trichromatic filters (red, green, blue) that simulate the response of the three types of cones in the retina.
The values read from the three filters are converted into numerical coordinates in standard color spaces — CIE Lab*, Yxy, LCh — and displayed as the measurement result.
Advantages of a Colorimeter
● Lower price compared to spectrophotometers
● Compact size and light weight
● High measurement speed
● Adequate for comparative checks of already-defined colors
Limitations of a Colorimeter
The main drawback of filter-based colorimeters is the accuracy of the spectral response. Physical filters do not exactly replicate the CIE standard sensitivity curves of the human eye. In lower-cost models this deviation can be significant: in extreme cases, the device can output incorrect coordinates — for example, blue values for a yellow sample.
Another drawback is the lack of spectral data: a colorimeter only provides the final coordinates, not the reflectance curve. This makes it impossible to detect metamerism, calculate coordinates under different illuminants, or supply data to color-formulation software.
How Does a Spectrophotometer Work?
A spectrophotometer analyzes color in a fundamentally different way: it measures the amount of light reflected by the sample at every wavelength across the visible range of 400–700 nm, typically in 10 nm increments. The result is a full reflectance curve — 31 independent data points — from which the colorimetric coordinates are calculated mathematically.
This approach offers three fundamental advantages over a colorimeter:
Higher precision: The full spectral curve eliminates the approximations introduced by physical filters. The Lab* coordinates calculated from the spectrum are more accurate and more stable over time.
Metamerism detection: Because the full spectral curve is available, a spectrophotometer can calculate the colorimetric coordinates under any standard illuminant (D65, D50, A, F2, LED). Two metameric samples show different reflectance curves even when their Lab* coordinates appear similar under one illuminant.
Spectral data for formulation development: The reflectance curve is the input data required by color-matching software and pigment-formulation development tools. Without spectral data, these programs cannot function.
The Spectrocolorimeter: The In-Between Solution
Between the trichromatic-filter colorimeter and the full spectrophotometer lies an intermediate category: the spectrocolorimeter.
A spectrocolorimeter analyzes the spectrum the way a spectrophotometer does, but with partial spectral coverage and lower resolution. The shape of the spectral curve between the actual measurement points may be partly interpolated. Compared to a trichromatic-filter colorimeter, it is significantly more precise and reliable — it doesn’t suffer from the typical approximation errors of physical filters. Compared to a full spectrophotometer, it offers a better price-to-performance ratio at a slightly lower level of precision.
3Color’s colorimeter line — the CP100 and CP200 models — are technically spectrocolorimeters: they incorporate spectral-analysis capability while retaining the ease of use and compact size typical of colorimeters.

Fig. 1: Deviations in the spectral curve of the CP100 spectrocolorimeter compared to the spectral standard.
Direct Comparison: Technical Parameters Side by Side
| Parameter | Colorimeter (Filter) | Spectrocolorimeter | Spectrophotometer |
| Principle | Trichromatic filters | Partial spectrum | Full spectrum, 400–700 nm |
| Typical repeatability | ΔE ≈ 0,10–0,20 | ΔE ≈ 0,04 | ΔE ≈ 0,02 |
| Inter-instrument agreement | ΔE ≈ 0,8–1,5 | ΔE ≈ 0,4 | ΔE ≈ 0,2 |
| Spectral data | No | Partial | Full |
| Metamerism detection | No | Limited | Yes |
| Multiple illuminants | Limited | Limited | Yes |
| Price | Low | Medium | Medium–high |
| Ideal for | Quick comparative checks | QC of defined colors | Strict QC, formulation, R&D |
Making the Decision: Asking the Right Questions
The choice between a colorimeter and a spectrophotometer doesn’t come down to budget — it comes down to the application. These questions help identify the right device:
Choose a colorimeter (or spectrocolorimeter) if:
● Your quality control is comparative: you’re checking samples against an already-defined, approved physical reference standard
● Your suppliers and customers don’t exchange spectral data
● You can accept a tolerance of around ΔE ≈ 1.0 against certified samples
● Color isn’t a critical parameter for the product’s commercial success
● You need a compact device for field or production-floor measurements
Choose a spectrophotometer if:
● Your quality control requires repeatability of ΔE ≤ 0.02 and inter-instrument agreement of ΔE ≤ 0.2
● Your suppliers or customers use spectrophotometers and exchange spectral data
● You need to detect metamerism or work across multiple standard illuminants
● You use color-matching or pigment-formulation software
● Color quality is a critical parameter for your business success or brand image
● You want a device that stays measurement-consistent for many years through regular calibration
Frequently Asked Questions
Can a colorimeter replace a spectrophotometer for quality control? It depends on the accepted tolerance and the complexity of the colors being controlled. For solid colors with tolerances of ΔE > 1.0 and no need for spectral data, a spectrocolorimeter may be sufficient. For metallic or pearlescent colors, or where documented traceability is required, a spectrophotometer is necessary.
What does inter-instrument agreement mean? Inter-instrument agreement indicates how closely the results from two different units of the same device type match when measuring the same sample. A high-quality spectrophotometer achieves an agreement of about ΔE 0.2, while a spectrocolorimeter achieves about ΔE 0.4. This parameter is critical when comparing measurements taken with different devices at different points in the supply chain.
Can a colorimeter detect metamerism? No — a trichromatic-filter colorimeter only measures color under the illumination conditions simulated by its internal filters. It cannot calculate colorimetric coordinates under different standard illuminants or compare reflectance curves. Detecting metamerism requires a spectrophotometer with full spectral data.
What’s the difference between repeatability and reproducibility in color measurement? Repeatability refers to the variation between consecutive measurements of the same sample taken with the same device under the same conditions. Reproducibility (or inter-instrument agreement) refers to the variation between measurements of the same sample taken with different devices. Both parameters are expressed in ΔE units and listed in each device’s technical specifications.
Is data from a spectrocolorimeter compatible with data from a full spectrophotometer? Partially. The Lab* coordinates are comparable between the devices within tolerance. However, the partial-spectrum data from a spectrocolorimeter isn’t suitable for use in formulation software that requires a full reflectance curve at 10 nm resolution.
Summary
Choosing between a colorimeter and a spectrophotometer is a technical decision that affects measurement quality for years to come. The colorimeter — especially the spectrocolorimeter — is the right choice for quick comparative checks with moderate tolerances. The spectrophotometer is essential when precision, traceability, and spectral data are process requirements.
Explore 3Color’s product range: colorimeters and spectrocolorimeters CP100 and CP200 for comparative quality control, the portable spectrophotometer SV-300, and benchtop spectrophotometers 9000neo and 9001neo for more demanding applications. Questions about which to choose? Contact our technical team for personalized guidance.
Discover Our Products
Discover Our Other Devices
Expand Your Device’s Capabilities with Comprehensive Software Integration